Steam Superheaters
A steam superheater is a heat exchanger that takes saturated steam from a boiler and heats it further at the same pressure, producing superheated steam: steam above its saturation temperature that is dry and carries no water droplets. Superheated steam is used where turbines, drying lines and high-temperature processes need hotter, drier steam than a boiler alone delivers.
Ekotek steam superheaters handle steam flows from 500 to 150,000 kg/h, with a superheated steam outlet temperature of 200–500 °C and a working pressure of 3–60 bar. Saturated steam inlet pressure is 6–50 bar or 6–60 bar, depending on the series. Two lines are available: the electric e-Superheater and the liquid/gas-fired Alev Series.
The right unit depends on steam flow, inlet pressure, target outlet temperature, the steam boiler already on site and the energy source available. Browse the models below, or send us your process data for a quotation.
Steam Superheaters
Alev Series - Liquid/Gas Fired Steam Superheater
- 500 kg/h - 150,000 kg/h Superheating Capacity
- Horizontal coil, liquid / gas fired
Steam Superheater
- Steam generation capacity from 500 kg/h to 50,000 kg/h
Where a Superheater Fits in a Steam System
Steam leaving the evaporating surfaces of a boiler is saturated. To raise its temperature without raising its pressure, it has to pass through an additional heating stage: the superheater. What comes out is no longer saturated steam but superheated steam, hotter at the same pressure and free of droplets.
A superheater can sit inside the boiler or be a separate unit with its own heat source. Ekotek uses the separate approach: an electric or burner-fired superheater connected to your existing steam line, so the superheated steam temperature can be set to match the process.
How Does a Steam Superheater Work?
- Saturated steam in: A steam boiler or steam generator sends its saturated steam to the superheater.
- Heating: Electric heating elements (electric models) or a burner and combustion chamber (liquid/gas models) add heat to the steam. Pressure stays constant while temperature rises.
- Superheated steam out: The steam reaches the required outlet temperature, set within the 200–500 °C range according to the process, and flows on to the consumer.
- Control: Outlet temperature, inlet pressure, steam flow and heat input (electrical power or burner) are monitored together, and safety limits prevent overheating above the set point.
Heating a superheater with no saturated steam flowing through it damages the coil or the shell. At start-up, steam flow is established first and heat input is then raised step by step.
Superheated Steam vs Saturated Steam
| Criterion | Saturated steam | Superheated steam |
|---|---|---|
| Definition | At the saturation (boiling) temperature for its pressure | Above the saturation temperature at the same pressure |
| Temperature and pressure | Pressure fixes the temperature | Temperature can be set independently at constant pressure |
| Moisture and droplets | May carry some wetness | Dry; carries no droplets |
| Heat transfer | Releases latent heat by condensing; effective for heating and sterilisation | Releases sensible heat first; preferred for turbines, drying and high-temperature processes |
| Effect on piping | Higher risk of condensate and erosion | Condensation is delayed in long lines; lower risk of droplet erosion on turbine blades |
| Typical use | Heating, sterilisation, direct process steam | Steam turbines, drying, high-temperature chemical and petrochemical processes |
If your process relies on direct condensing heat, saturated steam may be enough. If you run a turbine or need high-temperature, dry steam, you need a superheater. For the saturated steam source, see our steam boilers and liquid/gas-fired steam boilers.
Electric e-Superheater (KD Series)
The e-Superheater is an electrically heated steam superheater with a horizontal body. It needs no chimney and no fuel tank, which makes it a fit for plants with enough electrical capacity, sites with emission limits, or installations where a burner is not wanted.
- Steam flow: 500–150,000 kg/h (KD-1 to KD-34)
- Saturated steam inlet pressure (table): 6–50 bar
- Working pressure: 3–60 bar
- Superheated steam outlet temperature: 200–500 °C
- Design: horizontal body
- Energy source: electricity
If you need to produce steam electrically, see our electric steam generators. A superheater only superheats saturated steam that already exists; it does not make steam from water.
Alev Series Liquid/Gas-Fired Superheater
The Alev Series is a burner-fired steam superheater with a horizontal coil design. It is built to run on natural gas, LPG, LNG, propane, CNG, biogas, gas oil, diesel, fuel oil or a dual-fuel burner, and is chosen where electrical capacity falls short or where fuel is the more economical energy source.
- Superheating capacity (catalogue range): 500–150,000 kg/h
- Table models: from Alev Series 2 (2,000 kg/h) to Alev Series 150 (150,000 kg/h)
- Saturated steam inlet pressure (table): 6–60 bar
- Working pressure: 3–60 bar
- Superheated steam outlet temperature: 200–500 °C
- Design: horizontal coil
For burner selection and flue arrangements, see burners. For Alev Series quotations and technical drawings, send your request through our contact page.
Data Needed to Size a Superheater
- Current or planned saturated steam flow (kg/h) and inlet pressure (bar)
- Required superheated steam outlet temperature (°C) and process set point
- Load profile: continuous or variable, plus peak flow
- Energy available on site: electrical power and voltage, or natural gas, LPG or liquid fuel
- Existing boiler or steam generator model and steam line diameter
- Boiler house layout, flue (for liquid/gas units) and electrical panel capacity
- Plans for future capacity increases
With this data, superheater capacity, heat source type and safety equipment are sized together.
Industries and Applications
- Power and turbines: feeding dry, high-temperature steam to steam turbines
- Chemicals and petrochemicals: reactors and process lines that need high temperatures
- Drying: superheated steam for paper, textile, timber and ceramic drying lines
- Food: dry steam for high-temperature processing or ahead of sterilisation, where the process allows
- Textiles and paper: drying cylinders and high-temperature treatment
Auxiliary Equipment and Connection
The superheater connects to the outlet of the boiler or steam generator that produces the saturated steam. A typical installation includes:
- Inlet and outlet steam valves, a safety valve and drain lines
- Temperature and pressure sensors and a control panel
- On liquid/gas units: burner, fuel line and flue
- On electric units: power panel and protection devices
- Condensate management and steam line accessories
For boiler house equipment, see steam boiler room auxiliary equipment and steam boiler system equipment. Where flue gas heat recovery is needed, an economizer is also worth considering. The full range is listed under accessories.
Safety and Maintenance
- Never run the heat source without steam flow; dry running damages the coil or the shell.
- Check outlet temperature and pressure limits regularly and test the safety valve periodically.
- On liquid/gas units, keep burner tuning, flame supervision and flue gas checks up to date.
- On electric units, inspect heating element connections, insulation and panel protection.
- Watch the steam line for leaks and check flanges and gaskets; drain condensate pockets.
Our user manuals and service team can support you.
What Affects the Price of a Steam Superheater?
- Steam flow and required superheated steam temperature
- Inlet pressure and design pressure
- Energy type: electrical power, or burner and fuel system
- Materials and design (horizontal body or horizontal coil)
- Scope of automation, safety equipment and control panel
- Scope of delivery, installation and commissioning
Instead of a list price, we prepare a quotation based on your process data.
Request a Quote
Send us your steam flow, inlet pressure, target outlet temperature and the energy source on site through the contact form, or schedule a consultation. For the electric model, you can also send a request from the e-Superheater product page.
Frequently Asked Questions (FAQ) about Steam Superheaters
What is a steam superheater?
A steam superheater is equipment that heats saturated steam from a boiler further at the same pressure to produce superheated steam. The outlet steam is above its saturation temperature and carries no water droplets.
What is the difference between superheated and saturated steam?
Saturated steam is at the boiling temperature for its pressure, so pressure fixes its temperature. Superheated steam is hotter at the same pressure, its temperature can be set independently, and it is drier. For heating, saturated steam releases latent heat as it condenses; for turbines and drying, superheated steam is preferred.
How does a steam superheater work?
Saturated steam enters the superheater. Electric models add heat through heating elements, liquid/gas models through a burner. Pressure is held while temperature rises, and superheated steam at the set point leaves for the process.
What capacity range do Ekotek steam superheaters cover?
The catalogue range is 500–150,000 kg/h of steam. The electric e-Superheater covers this range from KD-1 to KD-34. The Alev Series table lists models from 2,000 kg/h to 150,000 kg/h, while the catalogue header gives 500–150,000 kg/h.
Should I choose the electric e-Superheater or the Alev Series?
The e-Superheater suits sites with enough electrical capacity where no flue or fuel system is wanted. The liquid/gas-fired Alev Series suits sites where natural gas or liquid fuel is more economical, or where electrical power is not sufficient. The choice depends on steam flow, temperature and energy cost.
What are the working pressure and superheated steam temperature?
Working pressure is 3–60 bar. In the catalogue tables, saturated steam inlet pressure is 6–50 bar for the electric series and 6–60 bar for the Alev Series. Superheated steam outlet temperature is 200–500 °C for both lines, with the process set point chosen within that range.
Which industries use steam superheaters?
They are used for steam turbines and power applications, chemicals and petrochemicals, drying lines, textiles, paper and other processes that need high temperatures. Where direct condensing heat is enough, saturated steam is usually sufficient.
Can a superheater be added to an existing steam boiler?
Yes. The superheater connects to the saturated steam outlet of an existing boiler or steam generator. Flow, pressure, line diameter and safety equipment must be compatible, so a technical check is made using your process and piping data.
What information is needed to select the right model?
Saturated steam flow (kg/h), inlet pressure (bar), required superheated steam temperature (°C), load profile, available electrical power or fuel, existing boiler details and installation conditions.
What equipment is needed alongside a superheater?
Inlet and outlet valves, a safety valve, temperature and pressure measurement and a control panel are the basics. Liquid/gas units add a burner and flue; electric units add a power panel. Condensate and steam line accessories are completed to suit the boiler house layout.
What should be considered for superheater safety and maintenance?
The heat source is never run without steam flow. Temperature and pressure limits, the safety valve, burner or heating element checks and line leaks are monitored regularly, and start-up is done gradually.
What affects the price of a steam superheater?
Steam flow, outlet temperature, design pressure, electrical or burner scope, materials, automation and the scope of installation and commissioning set the price. Quotations are prepared from your process data rather than a fixed price list.
Steam Superheaters Get a Quote
Contact us for more details about the product, solutions and services.
- Share your full name, company, and contact details to receive a fast response for this product category.
- The category and page context are added to the message so your request reaches the relevant sales team.
- You can contact our team directly for product selection, technical details, quotation, and application scope.
Requests submitted from this category page Steam Superheaters are delivered together with the page title.