Alev Series - Liquid/Gas Fired Steam Superheater
Alev Series is a liquid- and gas-fired steam superheater with a horizontal coil. It takes saturated steam from a steam boiler and heats it in a burner furnace at the same pressure, producing superheated steam. It is built for steam flows from 500 kg/h to 150,000 kg/h and working pressures of 3–60 bar.
Alev Series is a liquid- and gas-fired steam superheater with a horizontal coil. It takes saturated steam from a steam boiler and heats it in a burner furnace at the same pressure, producing superheated steam. It is built for steam flows from 500 kg/h to 150,000 kg/h and working pressures of 3–60 bar.
Technical Specifications
-
Superheating Capacity500 kg/h - 150,000 kg/h
-
Working Pressure3 - 60 bar
-
Design TypeHorizontal Coil Design
-
Fuel TypeLNG, Propane, CNG, Natural Gas, LPG, Biogas, Gas Oil, Diesel, Fuel Oil, Dual-fuel
-
Saturated Steam Inlet Pressure6 - 60 bar
-
Superheated Steam Outlet Temperature200 - 500 °C
The Alev Series steam superheater takes saturated steam from an existing steam boiler or steam generator and raises it above saturation temperature without changing the pressure, so the steam leaving the unit is superheated. Heat is supplied by a liquid- or gas-fired burner. Ekotek builds the Alev Series for a superheating capacity of 500 kg/h – 150,000 kg/h, a working pressure of 3–60 bar and a horizontal coil design. The superheater does not generate steam; it raises the temperature of the saturated steam already produced, to the level the process needs.
How the Alev Series Steam Superheater Works
The operating sequence can be summed up in four steps:
- Saturated steam inlet: Saturated steam from the boiler or generator enters the superheater coil tubes.
- Heating: Hot gases from the burner furnace heat the outer surface of the coil. As the steam travels through the tubes, its pressure is maintained and its temperature rises.
- Superheated steam outlet: Once the set temperature is reached, the steam leaves as dry superheated steam, without entrained water droplets, and goes to the consumer.
- Control: Outlet temperature, inlet pressure and steam flow are monitored; burner load is adjusted against these values.
The coils are cooled by the steam flowing through them. For that reason, steam flow is established first during start-up, and the burner is then brought in gradually. Firing the superheater with no steam flow can damage the coils.
Horizontal Coil Design
In the Alev Series, steam flows inside horizontally arranged coil tubes, while the combustion gases pass over the outside of those tubes. Heat is transferred through the tube wall into the steam. In this arrangement the steam heats up progressively as it travels along the heating surface inside the coil.
The size of the superheater is set by steam flow, inlet pressure and the required outlet temperature. Layout in the boiler house, the flue connection and the route of the steam line are assessed together at the design stage.
Fuel Options
The Alev Series steam superheater can be designed with burners for the following fuels:
- Gaseous fuels: natural gas, LPG, LNG, CNG, propane, biogas
- Liquid fuels: gas oil, diesel, fuel oil
- Dual-fuel: a burner option that can use gaseous and liquid fuel
The fuel is chosen according to the fuel system already on site, fuel cost and any need for a standby fuel. Burner options are described on our burners page.
Alev Series or Electric e-Superheater?
Ekotek steam superheaters are offered with two different heat sources:
| Criterion | Alev Series (liquid / gas) | e-Superheater (electric) |
|---|---|---|
| Heat source | Burner and combustion chamber | Electric heaters |
| Design | Horizontal coil | Horizontal shell |
| Flue and fuel system | Required | Not required |
| Typical fit | Sites where electrical capacity is insufficient or fuel is the more economical energy source | Sites with adequate electrical supply, an emission constraint, or where a burner is not wanted |
For the electric model, see the Steam Superheater – e-Superheater product page.
Applications
Superheated steam is drier than saturated steam and carries a higher temperature at the same pressure, so it is used in applications such as:
- Power and turbines: dry, high-temperature steam supply to steam turbines
- Chemical and petrochemical plants: reactor and process lines that need a higher temperature
- Drying: paper, textile, wood and ceramic drying lines
- Long steam mains: plants where condensation along the line needs to be reduced
- Food processing: where the process requires dry steam at a higher temperature
If the process heats by direct condensation, saturated steam is often sufficient. For a saturated steam source, see our liquid- and gas-fired steam boilers; for higher-pressure duties, see our water-tube steam boilers.
Information Needed for Selection and a Quote
To select the right Alev Series model we need the following:
- Saturated steam flow to be superheated (kg/h) and inlet pressure (bar)
- Required superheated steam outlet temperature (°C)
- Load profile: continuous or variable operation, and peak flow
- Fuel to be used, and any standby fuel
- Model of the existing boiler or generator, and steam line size
- Boiler-house layout and flue arrangements
- Any planned increase in capacity
Request an Alev Series Steam Superheater Quote
Send your process data through the quote form on this page or via our contact page. Our team will review capacity, fuel and control options with you. You can also schedule a consultation in person or online.
Frequently Asked Questions (FAQ) about Alev Series - Liquid/Gas Fired Steam Superheater
What does the Alev Series steam superheater do?
The Alev Series takes saturated steam from a steam boiler or steam generator and heats it further at the same pressure, producing superheated steam. Heat comes from a liquid- or gas-fired burner. Superheated steam is used on turbines, drying lines and processes that need a higher temperature.
Does a steam superheater generate steam on its own?
No. A steam superheater does not generate steam; it raises the temperature of existing saturated steam. The plant therefore needs a steam boiler or steam generator that supplies the saturated steam.
In what capacity and pressure range is the Alev Series built?
Alev Series steam superheaters are built for superheating capacities from 500 kg/h to 150,000 kg/h and a working pressure of 3–60 bar. In the catalogue capacity table, saturated steam inlet pressure is given as 6–60 bar.
What superheated steam outlet temperature is possible?
In the catalogue capacity table the Alev Series superheated steam outlet temperature is 200–500 °C. The exact outlet temperature is set at the design stage from steam flow, inlet pressure and the needs of the process.
Which fuels can the Alev Series run on?
It can be designed for natural gas, LPG, LNG, CNG, propane, biogas, gas oil, diesel and fuel oil. A dual-fuel burner that can use gaseous and liquid fuel is also available.
What is the difference between the Alev Series and the electric e-Superheater?
The Alev Series takes heat from a burner and needs a flue and a fuel system. The e-Superheater is electric and does not need a flue or a fuel tank. The Alev Series is chosen where electrical capacity is insufficient or fuel is more economical; the e-Superheater is chosen where the electrical supply is adequate.
Can an Alev Series superheater be added to my existing steam boiler?
The Alev Series is a separate unit connected to the existing steam line. Suitability is assessed from the boiler's steam flow and pressure, the steam line size, space in the boiler house and the flue arrangements.
What information should I provide for a quote?
Share the saturated steam flow (kg/h), inlet pressure (bar), required outlet temperature (°C), fuel to be used, load profile, existing boiler model, steam line size and boiler-house layout. With this information the appropriate model and burner can be selected.
Alev Series - Liquid/Gas Fired Steam Superheater Get a Quote
Contact us for more details about the product, solutions and services.
- Share your full name, company, and contact details to receive a fast response for this product.
- The product and page context are added to the message so your request reaches the right sales team.
- You can contact our team directly for technical details, product selection, quotation, and application scope.
Requests submitted from this product page Alev Series - Liquid/Gas Fired Steam Superheater are delivered together with the page title.